\begin{table}[ht!] \centering \caption{Comparison of the performance of timer functions. All tests were performed with a rate of \SI{100}{\kilo\hertz}, with 10 64-bit floating-point numbers per sample, \gls{rc} as service type, and with the InfiniBand node-type as node-type under test. Every test contains \SI{250000}{} samples.} \vspace{3mm} \label{tab:timer_comparison} \begin{tabular}{c | l l} \hlineB{3} \Tstrut \textbf{optimized environment} & \multicolumn{2}{c}{\textbf{missed samples}} \Bstrut \\ \Tstrut & \multicolumn{1}{c}{\textbf{\texttt{timerfd}}} & \multicolumn{1}{c}{\textbf{\gls{tsc}}} \\ \hhline{=|==} \Tstrut \NO & $\frac{12085}{250000}\cdot\SI{100}{\percent} = \SI{4.83}{\percent}$ & $\frac{3035}{250000}\cdot\SI{100}{\percent} = \SI{1.21}{\percent}$ \Bstrutlarger \\ \Tstrut \OK & $\frac{1692}{250000}\cdot\SI{100}{\percent} = \SI{0.68}{\percent}$ & \greencell{$\frac{1244}{250000}\cdot\SI{100}{\percent} = \SI{0.50}{\percent}$} \Bstrutlarger \\ \hlineB{3} \end{tabular} \end{table}